Skip to content
Bioelectronic Synergy Lab

2022

Research article Small

Drawn-on-Skin Sensors from Fully Biocompatible Inks toward High-Quality Electrophysiology

Hematoxylin-and-eosin-stained skin cross-sections on days 1, 2, and 3 comparing untreated control skin with skin coated in drawn-on-skin ink, showing no adverse tissue changes and confirming the ink’s biocompatibility.

Authors

S. Patel , F. Ershad , J. Lee , L. Chacon-Alberty , Y. Wang , M. A. Morales-Garza , A. Haces-Garcia , S. Jang , L. Gonzalez , L. Contreras , A. Agarwal , Z. Rao , G. Liu , I. R. Efimov , Y. S. Zhang , M. Zhao , R. R. Isseroff , A. Karim , A. Elgalad , W. Zhu , X. Wu , C. Yu

† These authors contributed equally.

Abstract

The need to develop wearable devices for personal health monitoring, diagnostics, and therapy has inspired the production of innovative on-demand, customizable technologies. Several of these technologies enable printing of raw electronic materials directly onto biological organs and tissues. However, few of them have been thoroughly investigated for biocompatibility of the raw materials on the cellular, tissue, and organ levels or with different cell types. In addition, highly accurate multiday in vivo monitoring using such on-demand, in situ fabricated devices has yet to be done. Presented herein is the first fully biocompatible, on-skin fabricated electronics for multiple cell types and tissues that can capture electrophysiological signals with high fidelity. While also demonstrating improved mechanical and electrical properties, the drawn-on-skin ink retains its properties under various writing conditions, which minimizes the variation in electrical performance. Furthermore, the drawn-on-skin ink shows excellent biocompatibility with cardiomyocytes, neurons, mice skin tissue, and human skin. The high signal-to-noise ratios of the electrophysiological signals recorded with the DoS sensor over multiple days demonstrate its potential for personalized, long-term, and accurate electrophysiological health monitoring.

Citation tools

Cite this paper

S. Patel, F. Ershad, J. Lee, L. Chacon-Alberty, Y. Wang, M. A. Morales-Garza, A. Haces-Garcia, S. Jang, L. Gonzalez, L. Contreras, A. Agarwal, Z. Rao, G. Liu, I. R. Efimov, Y. S. Zhang, M. Zhao, R. R. Isseroff, A. Karim, A. Elgalad, W. Zhu, X. Wu, C. Yu (2022). Drawn-on-Skin Sensors from Fully Biocompatible Inks toward High-Quality Electrophysiology. Small 18(36), 2107099. https://doi.org/10.1002/smll.202107099

BibTeX · Patel2022Drawnon

@article{Patel2022Drawnon,
  title = {{Drawn-on-Skin Sensors from Fully Biocompatible Inks toward High-Quality Electrophysiology}},
  author = {S. Patel and F. Ershad and J. Lee and L. Chacon-Alberty and Y. Wang and M. A. Morales-Garza and A. Haces-Garcia and S. Jang and L. Gonzalez and L. Contreras and A. Agarwal and Z. Rao and G. Liu and I. R. Efimov and Y. S. Zhang and M. Zhao and R. R. Isseroff and A. Karim and A. Elgalad and W. Zhu and X. Wu and C. Yu},
  journal = {Small},
  year = {2022},
  volume = {18},
  number = {36},
  pages = {2107099},
  doi = {10.1002/smll.202107099},
  url = {https://doi.org/10.1002/smll.202107099},
}